Allen Adams, PE, SE, Bentley Systems, Inc. / RAM

In May 2020, SE University welcomed Allen Adams, PE, SE, from Bentley Systems, Inc. / RAM, to present 2020 Practical Strategies for the Modeling and Analysis of Diaphragms.  Allen designated Operation HOPE – North County (https://www.operationhopeshelter.org/) for our SEU Speaker Inspires donation for the month.

The mission of Operation HOPE – North County is to provide a safe and supporting environment for families with children and single women who are experiencing homelessness as they rebuild their lives.

Allen shared, “Over the years I have had the privilege of seeing their good work, having worked on service projects with the Boy Scouts and through church that benefitted that organization. They provide a much needed service for a vulnerable group of people.”

Thank you, Allen, for helping structural engineers with your SE University session, and for your designation of Operation HOPE – North County as our SEU Speaker Inspires Organization of the Month!

 

 

SE University began the SEU Speaker Inspires program in 2015 as a way to “pay it forward”, enabling our speakers to designate a charity/organization of their choice for SE University to make a donation to help improve our world.

Calculating the exact material properties of diaphragms to include in your structural model can be a time consuming task. Often times, structures with semi-rigid diaphragms also take longer to analyze due to the additional degrees of freedom. Semi-rigid diaphragms can be more complex to analyze than their flexible or rigid counterparts. However, accurate analysis results may not be so hard to accomplish within a short amount of time.

In the May 2020 SE University session, Allen Adams, PE, SE, from Bentley Systems, Inc. / RAM, presented Practical Strategies for the Modeling and Analysis of Diaphragms. Allen explained the differences between flexible, semi-rigid, and rigid diaphragms and how these affect analytical results. He reviewed code requirements pertaining to diaphragms and shared how sensitive analytical models are to the various components of semi-rigid diaphragm models. Allen advised on balancing the necessary level of accuracy with business demands for speed and simplicity when modeling diaphragms.

Allen presented several case studies which examined varying diaphragm properties to see their influence on the structural analysis results. For example, Allen questioned how much influence does mesh size have on the analysis results? Allen used the same model with the diaphragm mesh varying from a 1 foot mesh to a 15 foot mesh. Assuming the 1 foot mesh is the most accurate, Allen examined the percent difference between using a smaller mesh versus a larger 15 foot mesh. The analysis results for the frame story shears, surprisingly showed a minimal difference between the smaller mesh and the larger mesh. However, the time required for the analysis to be complete was significantly higher for the smaller mesh. A more average mesh size on the order of 4 feet or 8 feet resulted in similar frame story shears while still completing the analysis in a shorter time frame similar to the larger mesh.

Allen also examined how material properties of the diaphragm affect the analysis results. Specifically, Allen examined how much influence does inaccuracy in the effective modulus of elasticity (E’) have on the results? Allen analyzed the same model while varying E’ from 500 ksi to 24000 ksi. Again, surprisingly, while the effective modulus of elasticity was varied by 48 times, the results only varied by 3.7 percent. While this is just one example, it shows that it is not necessary to spend hours nailing down the exact E’ of the diaphragm, especially in complex instances where it may vary throughout the same story. A close estimate will suffice to garner accurate results. There was some additional variability when examining the moment within the diaphragm as the E’ was varying, however, when a close estimate is assumed, the resulting moment remained accurate. Minimal variability was noted when examining the story drift at the frames, however there was significant differences noted in the drift away from the frames. Allen noted that it would be more appropriate to look at the drift at the frames rather than away from the frames for accurate drift results. Also, the drift results measured at points on the diaphragm away from the frames did not account for the stiffness added from the presence of gravity framing which would also limit those story drift results.

Overall, Allen’s case study examples proved to be enlightening for engineers that feel they must model the diaphragm down to the tiniest detail to get accurate analysis results. It is worth noting that having a general idea of the material properties will suffice and the model does not need to be so detailed that the analysis takes an extreme amount of time to complete.

Control joints (CJs) are necessary in reinforced masonry walls with minimal joint reinforcing to prevent thermal cracking. However, improper placement of CJs can negatively impact the structural capacity of the wall and lead to an inefficient design. What are the best methods to ensure an efficient and practically detailed masonry wall with CJs?

In the April 2020 SE University session, Sam Rubenzer, PE, SE, from FORSE Consulting, presented Masonry Checklist: Reviewing Structural Drawings. During the session, Sam offered insight on developing checklists of important items for masonry design and construction. He also reviewed important aspects of masonry design criteria and discussed best practices for element design, including advice on locating control joints and using masonry lintels.

Criteria for CJs in masonry walls will vary in different locations in the country due to different loading demands, and reinforcement and construction techniques common to each area. For example, it is common to have more horizontal reinforcement in high seismic areas and those areas already use less CJs. However, many midwestern states with low seismic loads commonly use minimal horizontal reinforcement only in mortar joints, and therefore require more CJs be used.

There are commonalities for CJ placement within all areas. When placing CJs in masonry walls, Sam noted that placing them too closely will result in shear walls that have significant losses in their lateral resistance capacity; However, spacing them too far apart will potentially result in thermal cracking throughout the wall. Sam offered some basic guidelines for placing control joints for maximum effectiveness.

First, CJs should not be placed adjacent to wall openings. As you can see in the example below, a perforated shear wall can have 300% the capacity of two shorter walls being split near the opening.

Additionally, you may need to design some walls with increased horizontal reinforcing in order to eliminate some CJs. For example, long walls with repetitive door openings, as shown below, do not offer a practical location for a CJ. Designing these walls with additional horizontal reinforcement can allow the wall to maintain its lateral resistance without the need for a control joint within the area around the doors. NCMA TEK Guide 10-3 provides guidance on horizontal reinforcement requirements.

Sam also suggested the use of masonry lintels in order to reduce the need for CJs. Using masonry lintels creates a more rigid wall which eliminates stress concentrations which can develop when using steel lintels with CJs at repetitive wall openings. In the same example above, a continuous masonry lintel further improves the rigidity of the wall, increases the lintel’s capacity to resist load, and increases the wall area’s ability to resist in-plane and out of plane loading. Also, the continuous lintel reinforcement can contribute to the overall reinforcement required to reduce the need for CJs in that area.

Sam strongly recommends showing CJs on plan and/or elevation rather than within structural notes. Also, it can be helpful to delineate these locations on elevation since architects tend to show movement joint location on their elevations, as well. Using these tips from Sam about practical CJ spacing, masonry walls designs become more efficient and stronger and reduce the likelihood for cracks due to thermal movements.

Allen Adams, PE, SE, Bentley Systems, Inc. / RAM

In May 2020, SE University welcomed Allen Adams, PE, SE, from Bentley Systems, Inc. / RAM, to present 2020 Practical Strategies for the Modeling and Analysis of Diaphragms. Allen designated Operation HOPE – North County (https://www.operationhopeshelter.org/) for our SEU Speaker Inspires donation for the month.

The mission of Operation HOPE – North County is to provide a safe and supporting environment for families with children and single women who are experiencing homelessness as they rebuild their lives.

Allen shared, “Over the years I have had the privilege of seeing their good work, having worked on service projects with the Boy Scouts and through church that benefitted that organization. They provide a much needed service for a vulnerable group of people.”

Thank you, Allen, for helping structural engineers with your SE University session, and for your designation of Operation HOPE – North County as our SEU Speaker Inspires Organization of the Month!

 

 

SE University began the SEU Speaker Inspires program in 2015 as a way to “pay it forward”, enabling our speakers to designate a charity/organization of their choice for SE University to make a donation to help improve our world.

When designing large roof deck diaphragms, the shear requirements at the perimeter often far exceed those in the field, so much so that the more commonly used lighter gage decks and typical attachment designs can be inadequate.  What is the best way to increase the deck diaphragm shear strength while also minimizing any cost increases?

In June 2018, Keith Cullum, PE, from Simpson Strong-Tie gave a presentation on Steel Deck Diaphragm Attachment. Keith reviewed the function and components of a steel deck diaphragm and compared common attachment methods. He also talked about appropriate standards and building code references and frequent challenges associated with designing steel deck diaphragms.  At the end of the session, a question was asked about the best approach to increasing the deck diaphragm shear capacity in the most cost-effective manner.  Watch this short video to hear Keith explain his step-wise strategy to increasing shear capacities.

To learn more about steel deck attachment and access additional design resources, please review our other blog post about Steel Deck Diaphragm Calculators and Resources from Keith Cullum’s SE University session.

SE Solutions would like to do our part to help others in need given this extremely difficult time for many people across the country.  In response to the many Americans facing unemployment and economic hardship as a result of the coronavirus outbreak, SE Solutions would like to assist others in need through Feeding America.

The Feeding America network is the nation’s largest domestic hunger-relief organization.  Feeding America is working hard to meet the increased demand on local food banks throughout the country.

Therefore, for anyone willing to make any donation to Feeding America (https://www.feedingamerica.org/about-us/press-room/feeding-america-establishes-covid-19-response-fund-help-food-banks-during), we will contribute $100.00 for each donation, up to a total of $3000 from SE Solutions.  Simply email [email protected] and let us know you contributed.  We would like to acknowledge those who contributed in our newsletter and on our blog, so please let us know if you would like to be acknowledged.

Thank you for being part of our SE Solutions community and we hope everyone is staying safe and healthy.

Steel fiber reinforced concrete (SFRC) is still somewhat new to many structural engineers, but its uses are gaining in popularity, and structural engineers should become more familiar with its use, design, and practical applications.  Clients are always looking for new, innovative, and cost effective solutions, and SFRC may be the answer on your next project.

In the February 2020 SE University session, Claire Gandee, from Bekaert, presented Steel Fiber Reinforced Concrete.  Claire reviewed the basics of steel fiber reinforced concrete (SFRC) and covered the applicable code references for the design of SFRC.  She also covered the design approaches typically used for SFRC and made practical recommendations for specifying and for the placement/finishing of SFRC.  Claire explained the benefits of using SFRC including possible economic savings.

Claire reviewed many of the practical aspects of placing and finishing when using SFRC.  To hear Claire cover many of her frequently asked questions about SFRC, watch this short 4 minute video:

 

Matthew Rechtien, PE, Esq., Walter P. Moore

In March 2020, SE University welcomed Matthew Rechtien, PE, Esq., from Walter P. Moore, to present 2020 Engineering Ethics Update.  Matt designated Friends of Perryville Battlefield (https://www.friendsofperryville.org) for our SEU Speaker Inspires donation for the month.

Matt shared, “On October 8, 1862, nearly 8,000 Americans fell in the drought-parched Chaplin Hills of Kentucky during the Battle of Perryville. Perryville played a pivotal role in our nation’s most impactful event. Although the clash is oft-forgotten, those Americans should be remembered and that sacred ground, one of the most pristine civil war battlefields remaining, should be protected. The Friends of Perryville Battlefield is committed to both missions, which I am humbled to advance.”

Thank you, Matt, for helping structural engineers with your SE University session, and for your designation of Friends of Perryville Battlefield as our SEU Speaker Inspires Organization of the Month!

 

 

SE University began the SEU Speaker Inspires program in 2015 as a way to “pay it forward”, enabling our speakers to designate a charity/organization of their choice for SE University to make a donation to help improve our world.

Steel fiber reinforced concrete (SFRC) is gaining in popularity, especially in designs for industrial slabs on grade.  Steel fibers can add strength and increase fatigue resistance, impact resistance, and crack control which make it ideal for large scale slabs where the use of welded wire fabric can be eliminated.  The addition of steel fibers may be an economical option, but if you’ve never used them, you might wonder what is the best method to properly specify SFRC?

In the February 2020 SE University session, Claire Gandee, from Bekaert, presented Steel Fiber Reinforced Concrete.  Claire reviewed the basics of SFRC and covered the applicable code references for design.  She also covered the design approaches typically used for SFRC and made practical recommendations for specifying and for the placement/finishing of SFRC.  Claire explained the benefits of using SFRC, including possible economic savings.

Claire shared the critical information that should be included when specifying SFRC.  However, it is most important to be sure the contractor and others on the project can readily find the information, and this is best achieved by including it in the specs within the 03 33 00 Cast In Place Reinforcing or alternately within the 03 24 00 Fibrous Reinforcing, including a reference in the 03 33 00 section to be sure it is not missed by the contractor.  ASTM C1116 is a standard specification for Fiber Reinforced Concrete which can be referenced in supplement to performance and material properties of the steel fibers utilized in a project.

Within the specs, the following performance and material requirements should be delineated:

Claire also provided typical drawing notes that give examples of specifying SFRC on construction documents:

These examples provide a good basis to get started using SFRC on projects where performance improvements help the end-user, and/or when it can save time and money for clients.  While steel fiber reinforcing may be new to some, open communication with the contractor and manufacturer can eliminate any mishaps when using SFRC on your first project.

Given the current situation with many people needing to transition to working from a home based office, Sam Rubenzer, SE, from FORSE Consulting prepared a 15 minute video with tips for structural engineers.  You can view this at no charge by clicking on this video link.
We hope everyone stays healthy and safe.

1 10 11 12 13 14 15 16 30
SE Job Alert Notifications

SE Job Alert allows us to notify you quickly when new exciting positions become available. Your information will not be sold or shared with other companies.

Sign Me Up